Page view 8
23602 /8
10. Galvanometer installation
Tester: Meter tester (MA-00-01)
Needle must be absolutely horizontal between 15 and 8. Check
the movable range of the needle in the upper and lower part.
11. Shutter release adjustment
As shown in Fig. 19, when mirror .housing is released, dimension between Shutter Actuator
plate (B61) and minor housing foot. should be kept at 9.4 ±10mm.
The longer Shutter actuotor plate (B61) will break Shutter mechanism (E000), and the shorter
one will never make it (E000) function.
Fig. 18
Fig. 19