PRODUCT No. 23602ASAHI PENTAX SERVICE MANUAL

Page 2 - B. Disassembly

23602 /9D. LubricantsG21 — Mainly usedG31 — 0-B25, 0-B48, 0-B68, 0-B22L — On rewind shaft (D6)E. Special toolsFig. 20

Page 8

23602 /1B. DisassemblyThere are some parts which have to be taken off with careful treatment.1. Top cover (A300) removalWind lever should be set at cl

Page 9 - 23602 /8

23602 /23. P.C. board attern assembly (T100) removalP.C. board pattern assembly (T100) can be takenout with or without removing Front Board.Pull it ou

Page 10 - E. Special tools

23602 /3C. Assembly and adjustmentsSome parts should be assembled and adjusted. with careful treatment as shown in the following.1. Winding stopper as

Page 11

23602 /4Wind up top 2nd mech. plate assembly (C200) with driver and loosen wind shaft withoutmoving main gear. Then give back-tension to sprocket gear

Page 12

23602 /56. Blue needle adjustment(a) Set shutter dial to “AUTO”. Install Idle gear holder assembly (0-A12) gearing 2/3 portionwith the gear of (ga1van

Page 13

23602 /6Procedure(a) No clearance is allowed between release plate (A503) and the lever of shutter mechanism(E000). and also the lever should not be p

Page 14

23602 /79. Shutter speed adjustment:Testers:Light value correction unit. TSST-3A. T adjuster (or battery), ESST-1A, digital counter,diaphragm setting

Page 15

23602 /810. Galvanometer installationTester: Meter tester (MA-00-01)Needle must be absolutely horizontal between 15 and 8. Checkthe movable range of t