23602 /1
B. Disassembly
There are some parts which have to be taken off with careful treatment.
1. Top cover (A300) removal
Wind lever should be set at closed position before taking off top cover.
2. Photo sensor circuit board assembly (T300) removal
K2 camera is controlled with very small electric current (ex. 200pA or 300pA), therefore all
electric parts should be treated carefully, especially, photo sensor circuit board; it is so sensitive
that it should not be touched with bare hands.
AT PREADVANCE ANGLE
Fig. 2
AT CLOSED POSITION
Fig. 1
Fig. 3