Procedure
(a) No clearance is allowed between release plate (A503) and the lever of shutter mechanism
(E000). and also the lever should not be pushed by release plate.
(b) After shutter cocking, adjust
clearance to 0.3mm between Mirror
Actuator lever hook plate assembly
(0-B48) and its hitting part.
(Adjusting screw 1)
(c) Shutter stroke adjustment
Depressing shutter button gradually,
shutter starts working at 2.3mm ±0.2
deep from original position.
(Adjusting screw 2)
(d) Self timer stroke
0.1 mm deeper than shutter stroke
(Adjusting screw 3)
8. Funchon check of SWp
“ON” When release button is gradually depressed and before it reaches to keep-position, SWp
should be on”.
“OFF” When wind lever is set at closed position.
When release button is depressed with “Lock”